7.3 Recommendation for a casting process
Figure 34: further suggestions of casting programs
> Switch on water-, protective gas and vacuum supply.
> Prepare crucible with thermocouple. Switch on mains switch
(booting takes about 10 seconds).
> Fill in casting material.
> Put in preheated flask (620...650 °C).
> Close and lock casting chamber secure.
Figure 35: safe handling of lock
Close the lock with the ball of hand. Hold the
hand open and use a glove.
> Start your casting program with “Start” button.
> If casting temperature is reached press “Start”-button again for
building up vacuum (melting pressure).
> After 10 seconds please press the button on the handle and tilt
the chamber uninterrupted clockwise til the catch. Release the
button on the handle to lock the unit in the tilted position. During
the tilting the unit automatically switches from vacuum (melting