move ten pixels once.
⚫ Press the M (5) button briefly to switch the direction between X-axis and Y-axis.
⚫ Delete the defective pixel with a short press of the Power (7) button When the pixel has been successful deleted, the Add message
will appear on the PIP window for a short time.
⚫ Then, delete the next defective pixel by moving the cursor across the display.
⚫ Press the Power (7) button briefly in the same position as the calibrated defective pixel to
cancel the pixel correction, and the Del message will appear on the PIP window for a short
time. But it is only limited to not exiting this correction.
⚫ The amount of defect pixels changes each time adding or deleting pixels correction.
⚫ The PIP and the prompt information will move to the upper left of the screen when cursor
moves near the lower left corner.
⚫ Press and hold the M (5) button until display shows “Do you want to save these settings?”
and “Yes” and “No” options.
⚫ Press the Up (6) / Down (4) button briefly to select ‘Yes’ to save and exit, or select ‘No’ to
cancel saving and exit.
⚫ Confirm your selection with a short press of M (5) button.
⚫ If Yes is selected, a 5-second Saving countdown appears on the screen. It will exit to the home screen after the prompt Saved
successful appears.