Super Capacitor Fault Conditions and Precautions
If a Super Capacitor leaks, gives off a bad odor, generates heat, becomes discolored
or deformed, or in any way appears abnormal during use, recharging or storage,
immediately remove it from the system and stop using it. Here are some of the
conditions that might trigger Super Capacitor fault.
The temperature sensor on the systems charger circuit reports a
temperature reading exceeding the pre-set threshold. The charger
circuits will enter a low-power and self-protection state.
A Super Capacitor module has been charged for more than ten (10)
minutes. A timer is embedded with the charger. When this occurs, the
charger will enter a timer fault state. Charging will resume automatically
after you remove/re-install the Super Capacitor module or reset the
system.
Follow these precautions when you install the supercapacitor battery.
Use the replacement supercapacitor supplied by your distributor. Use of
capacitors provided otherwise will void your warranty.
Dispose of used Super Capacitor at authorized battery disposal sites
only.
Do not place a Super Capacitor near a heat source.
Do not immerse the Super Capacitor in water or expose it to other forms
of liquids.
Do not disassemble or modify the Super Capacitor.
Do not pierce the Super Capacitor with a sharp object, strike it with a
hammer, exert pressure on it, or throw it.