Once Mounted
Once the enclosure has been mounted, you may refer to the User Manual that came
with your system for further instructions on completing the hardware installation
process. The User Manual will go on to explain details on installation / maintenance
of hard drives, controllers, optional modules (Super Capacitor battery, CBM, etc.),
cooling modules, power supplies, cable connections, topology configurations, etc.
Safety Reminders
If you must relocate the enclosure after installation
Cease all input / output transactions, shutdown the system, disconnect all the cables
(please refer to the User Manual for details)
Empty all drive bays (hard drives + hard drive trays) and transport them separately in
safe packaging
Modules came installed within the enclosure need not be removed
When the system is in operation
Module and drive bays must not be empty! They must have a dummy cover / plate in
place to stabilized internal airflow!
Should a module fail, leave it in its place until you have the replacement item on-hand
to take its place
Allow at least 18~20cm of clearance space at the rear of the enclosure for ventilation
Avoid touching the PCB and gold-finger connections.