EasyManua.ls Logo

Infortrend DS1012R2C000D-SFP - SAS Expansion Enclosure Configuration

Infortrend DS1012R2C000D-SFP
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85
SAS Expansion Enclosure Configuration
The SAS expansion port connects to expansion enclosures. For dual-controller
systems, each expansion port connects a controller to a corresponding expansion
controller making fault-tolerant links to different SAS domains.
The following principles apply to storage system and expansion enclosure
connections:
Dual-controller storage system connects to dual-controller expansion
enclosures.
Single-controller storage system connects to single-controller expansion
enclosures.
A longer cable is available for making expansion links with a dual-controller
configuration. A longer cable is required if connections to expansion
enclosure s are made from two opposite directions. Routing through two
different connections can avoid loss of data links if one enclosure fails in
between.
There is a rotary ID switch on every expansion enclosure
that is manually configured using a flat blade screwdriver.
Configuring enclosure IDs:
The configurable IDs for expansion enclosures are from 1 to 15. Usually the
numbering starts from the one closest to the managing storage enclosure.
Make sure a unique ID is configured on each expansion enclosure so that
the SAS WWN addresses of disk drives can be properly assigned. The
storage system firmware automatically manages these addresses.

Table of Contents