EasyManua.ls Logo

Infortrend S12 Series - Page 97

Infortrend S12 Series
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EonStor / EonStor DS S12/S16/S24 Series
alternate
paths to the same logical drive.
RAID configuration
2 logical drives (each has 8 member drives). More
logical drives can be created from drives in JBOD.
LD0 mapped to CH0 AID, CH1 BID, CH2 AID and CH3
BID; LD has to be assigned to both controllers A and
B to enable remote replication.
LD1 mapped to CH1 BID, CH0 AID CH3 BID and CH2
AID; LD has to be assigned to both controllers A and
B to enable remote replication.
NOTE
In the event of single controller failure, a logical drive is accessed through the
host IDs managed by the alternate RAID controller. Host IDs and port IPs do
not fail-over to the surviving controller. Therefore, the EonPath multi-pathing
driver is necessary for path redundancy and controller failover.
97

Table of Contents

Related product manuals