1.3.1.2.7 MDB Slave
iUC180 contactless reader unit can be connected by MDB slave. The connector
type is MDB 6 pins (Mini – Fit series 87827 (MOLEX)).
iUC180 is powered on the MDB connectors by power supply 12 to 30V DC (30V
is a maximum).
A ferrite B & F ELECTRONICS CO.,
LTD. ref MD-05-265C or equivalent must be
added on the power cable.
1.3.1.2.8 MDB master (optional)
The iUC180 contactless reader unit can be connected by MDB master if option
available. The connector type is MDB master 8 pins (Mini Fit series 87827
(MOLEX)).
iUC180 does not support EXE power supply.
A Würth ferrite ref 74271222 or equivalent must be added with two turns on the
cable.
Pin N° Function
1 Vin
2 GND
3 NC
4 MDBS_RXD
5 MDBS_TXD
6 MDBS_COMMUN
Pin N° Function
1 NC
2 NC
3 NC
4 NC
5 MDBM_RXD
6 ISO_GND
7 MDBM_TXD
8 ISO_GND