©2008 Ingersoll Rand Company Page 23
continuously and remain on until the
maintenance is performed and the timers reset.
Reset Maintenance Timer [Std] – Once
maintenance has been performed, the following
steps should be taken to reset the maintenance
timer:
With unit stopped and power still applied to
controller, Press Menu button which will bring up
the code screen. From Pass code screen enter
0101. [Press green (enter) button {middle of
cluster} while on the first digit to enter 0, use
arrows to change second digit to 1 and press
green (enter) button to proceed to third digit,
continue in this manner until 0101 has been
entered].
Display should change to P00 flashing.
Using up and down arrows, select P03 and
press enter.
Using up and down arrows, select Sd (Service
due) and press enter, the Sd should stop
blinking and now the counter numbers should be
blinking, middle of the bottom display line.
Using up arrow, change the right side of the
display from Mn to Rst and press enter.
The counter should change to default 2000
unless Maintenance timer has been adjusted to
a lesser number and the Sd should now be
blinking again.
Press the red C button until display returns to
AE. You have now exited out of the
programming menu. If the wrench icon is still
displayed, please contact local service
representative. If a value less than 2000 hours is

Table of Contents