©2008 Ingersoll Rand Company Page 37
Sh 6 or 10 6 6
La 0-1 (Off/On) 0 0
Rp
0=100psi
1=125psi
2=140psi
3=210psi
4=7.5bar
5=8.5bar
6=10bar
7=14.5bar
0 0
Real Clock Function
With a standard configured controller, the real
time clock will be used to count down the 8760
hours before maintenance. This time is reset
when the maintenance hour indicator is reset.
The customer will not be able to view the clock.
With an enhanced configured controller, the real
time clock is accessible to the customer and
technician and once set at compressors
commissioning the display will show current time
and date. The real time clock is capable of
running when the power is removed from the
controller and should be able to maintain the
current date and time during power outages for
up to 4 years. This real time clock does not
recognize day light savings time and must be
adjusted accordingly.