Programming the SmartLink-GP 31
Programming manual
3.9 Associating incoming and outgoing
calls with actions
Figure 7 - Phone number functions
SmartLink-GP can identify up to 100 phone numbers. Caller ID can be
applied to incoming calls or SMS texts and outgoing calls. Caller ID must be
enabled otherwise caller/sender identification will not be possible.
Incoming calls can either have no effect or be programmed to activate the
outputs or the incorporated buzzer. Incoming SMS texts can be diverted to a
pre-set number, used for status enquiries or to activate the outputs or the
incorporated buzzer. Outgoing calls to black-list numbers can be barred. The
SmartLink-GP accepts five numbers with wildcard, that is, with the operator
‘*’ that accepts any digit (e.g. “390611*” indicates all Rome numbers that
start with “11”). The five numbers concerned must occupy the first five
positions in the list.
SmartLink-GP does not answer incoming calls but on caller identification,
generates the specified action (e.g. activate an output) and ends the call
Input - Line termination
The line termination type determines the logic of the intrusion control
panel input statuses:
Input - 24h
If 24h is not selected, only Short-circuit
and Tamper will be monitored during panel
disarmed status. If 24h is selected, all
conditions will be monitored, even when
the panel is disarmed.
For example, this option
is useful for duress and
device tamper reports.
Para-
meter
Description Note