EasyManua.ls Logo

Inovance IS300 Series - Page 24

Inovance IS300 Series
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter4FunctionCodeTable
23
Function
Code
Parameter Name Setting Range Min. Unit Default Property
gain 2
F2-04
Speed loop
integration time 2
0.01–10.00s 0.01s 0.30s
F2-05 Switchover frequency 2 F2-02 to max. frequency 0.01 Hz 10.00 Hz
F2-06
Slip compensation
coefficient
50%–200% 1% 100%
F2-07
Time constant of speed
loop filter
0.000–0.100s 0.001s 0.000s
F2-08 Torque control
0: Invalid
1: Valid
1 0
F2-09
Torque upper limit
source
0: F2-10
1: AI1
2: AI2
3: AI3
4: Reserved
5: Via communication
Analog input corresponds
to F2-10.
1 0
F2-10 Torque upper limit 0.0%–250.0% 0.1% 200.0%
F2-11 Encoder PPR 1–65535 1 1024
F2-12 Reserved - - -
F2-13 Shaft D current loop Kp 0–65535 1 50
F2-14 Shaft D current loop Ki 0–65535 1 50
F2-15 Shaft Q current loop Kp 0–65535 1 50
F2-16 Shaft Q current loop Ki 0–65535 1 50
Group F9: Fault and Protection Parameters
F9-00
Motor overload
protection selection
0: Disabled
1: Enabled
1 1
F9-01
Motor overload
protection gain
0.20–10.00
0.01 1.00
F9-04
Braking voltage
threshold
120%–150% (100%
corresponding to 530 V)
1% 130%
F9-12
Input phase loss
protection
0: Disabled
1: Enabled
1 1
F9-13
Output phase loss
protection
0: Disabled
1: Enabled
1 1
F9-14
Runaway speed
deviation
0.50–50.00 Hz 0.01 Hz 10.00 Hz
F9-15
Detection time of
runaway fault
0.0s: No detection
0.1s–20.0s
0.1 10.0s
F9-16 Motor temperature 0: Disabled 1 0