- 152 -
Speed protection
deviation
Factory default
value
10.00Hz
F9-14
Setup
range
0.50Hz ~
50.00Hz
It is used to set the frequency
deviation value of the motor speed
deviation. (The deviation value
between motor actual operating
frequency and command
frequency.
Speed deviation
protection time
Factory default
value
10.0s
F9-15
Setup
range
0.0s disable
0.1s ~ 20.0s
0.0s(protection
inenabled)
0.1s~20.0s
It is used to set speed deviation
protection time.
Motor temperature
protection selection
Factory default
value
0
F9-16
Setup
range
0:Inenabled
1:Enabled
Select whether or not to protect the
motor temperature overheating.
Motor temperature
protection mode
Factory default
value
0
F9-17
Setup
range
0:DI signal
input
1: AI 1:analog
input
2-3: Reserved
Select the motor temperature
overheating protection mode
It is used to record the fault types of driver for the resent three times: 0
indicates no fault, while 1 to 24 indicates ERR01 to ERR24. Refer to
Chapter 7 for details.
F9-18
The First fault
type
F9-19
The Second fault
type
F9-20
The the most
recent fault type
0~45