- 155 -
Motor
specifications
solidification
Factory
default value
0
FP-02
setup
instroution
When the motor specifications solidification parameter is non-zero, the
following parameters will not be able to change:
F1-00: Motor type selection
F1-01:Rated power
F1-02:Rated voltage
F1-03:Rated current
F1-04: Rated Frequency
F1-05:Rated rotation speed
F1-15:Back EMF
FP-03: Injection molding machine specifications solidification
Commissioning introduction:
It can not only realize motor specifications solidification,but also set the “ motor
static tuning ” (F1-16 = ” “ 1) and “ AI zero drift auto correction” (A3-20 = “ 0 ”),
after that,injection molding machine is able to realize running.Then adjust
PID, and the injection molding machine parameter adjustment is ended.
Injection molding
machine
specifications
solidification
Factory
default value
0
FP-03
setup
instroution
When the parameter of injection molding machine specifications solidification
is non-zero, the following parameters can not be changed.
F1-00: Motor type selection
F1-01: Rated power
F1-02: Rated voltage
F1-03: Rated current
F1-04: Rated Frequentcy
F1-05: Rated rotation speed
F1-15: Back EMF
F2-00: Speed loop proportional gain 1
1 05 17
Motor manufacturer
number
Motor rated torque
divided by 10
Motor rated rotation
speed divided by
100
01 012
Injection molding machine
manufacturer number
Injection molding
machine divided by 10