- 156 -
F2-01 Speed loop integration time 1
F2-03 Speed loop proportional gain 2
F2-04 Speed loop integration time 2
F2-10 Torque upper limit
FP-02Motor specifications solidification
Commissioning introduction:
It can not only realize injection molding machine specifications
solidification,but also set the “ motor static tuning ” F1-16“1”and “ AI zero
drift auto correction ” A3-20“0”, then the injection molding machine
parameter adjustment is ended.
User Password 2
Authorization for
FP-05function
code
Factory
default value
0
FP-04
Ssetup range 065535
Set any one of the non-zero number, password protection function is taken into
effect.
0000Clear a previously setup user passwords 2 value, and make password
protection function inenabled.
After setup the user password 2, and re-entry into parameter setup State, if the
user password 2 is incorrect, you can only view the parameter, you cannot
modify the parameters.Please keep the user's password 2in mind .If you
accidentally by mistake or forgot,please contact the manufacturer.
Function code
setup values in
real time saved
Factory
default value
0
0 No operation
FP-05
Setup range
1 Save the currently set values for all the
function code
1Save the currently set values for all the function code,It can be restored By
FP-01“3”.