- 35 -
1)Description of main circuit terminals of single-phase servo driver:
Terminals Name Description
RST R
S and T
Input
terminal of
three-phase
power
supply
AC single-phase 220V power connection point
(+) (-)(+)
and (-)
Negative
and positive
terminals of
DC bus
Shared DC bus input point (connection point of
external braking unit of above IS300T070
included
(+)PB(+)
and PB
Connecting
terminal of
brake
resistor
Connection point of Brake resistor of below
IS300T050(included)
P(+)P
and (+)
Connection
terminal of
external
reactor
Connection point of external reactor above
IS300T140(included)
UVW U,
V and W
Output
terminal of
servo driver
Connect the three-phase motor
Earth
terminal
Earth terminal
3) Precautions on Wiring:
a Input power R, S and T:
The cable connection at the input side of the servo driver has no phase
sequence requirement.
b DC bus (+) and (-) terminals:
Note that the (+) and (-) terminals of DC bus have residual voltage right
after power-on. It needs to wait until the CHARGE indictor is OFF and
make sure that the voltage is less than 36V prior to wiring connection.
Otherwise there may be danger of electric shock.
When selecting external brake unit for the driver of above IS300T07
(inculded), the poles of (+) and (-) shall not be connected reversely, or it