- 82 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F9-10
T/A1-T/B1-T/C
1Faulty rely
action selection
during the fault
auto reset
T/A1-T/B1-T/C
1
0:No action
1: Action
1 0
F9-11
Fault auto-reset
interval
Fault auto-reset
interval
0.1s100.0s 0.1s 10s
F9-12
Input phase loss
protection
selection
Input phase loss
selection
0: Inenabled
1: Enabled
1 1
F9-13
Output phase
failure protection
selection
Output phase
failure selection
0: Inenabled
1: Enabled
1 1
F9-14
Velocity
protection
deviation
Velocity
protection
deviation
0.50Hz50.00Hz 0.01Hz 10.00Hz
F9-15
Velocity deviation
protection time
Velocity
deviation
protection time
0.0s Disable
0.0s Protection
inenabled 0.1s
20.0s
0.1 10.0s
F9-16
Motor temperture
protection
selection
Motor temperture
protection
selection
0: Inenabled
1: Enabled
1 0
F9-17
Motor temperture
protection mode
Motor temperture
protection mode
0:D1 Signal input
1:A1 analog input
2-3:Reserved
1 0