- 83 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F9-18 The first fault type
The second fault
type1
F9-19
The second
failure type
The second
failure type
0: No fault
1Reserved
2: Speed-up over
current(Err 02)
3:Speed-down over
current(Err 03)
4: Constant speed
over current (Err 04)
5: Speed-up over
voltage (Err 05)
6: Speed-down over
voltage (Err 06)
7: Constant speed
over voltage (Err 07)
8: Reserved
9: Under voltage
failure (Err 09)
10: Servo driver
overload (Err 10)
11: Motor overload
(Err 11)
12: Input phase
failure (Err 12)
13: Output phase
loss (Err 13)
14: Radiator
overheating (Err 14)
15: External fault
(Err 15)
16: Communication
fault (Err 16)
17: Contactor fault
(Err 17)
18: Current detection
fault (Err 18)
19: Motor tuning fault
(Err 19)

Table of Contents