Acceleration/Deceleration mode 3 3 
 
 0 : Linear acceleration/ deceleration 
3:  S-curve acceleration/ deceleration C 
 
Time proportion of S-curve at Accel start 80.0 80.0 
 
 0.0% to Min[(100.0% - F6-09), 80%] 
 
Time proportion of S-curve at Accel end 10.0 10.0 
 
 0.0% to Min[(100.0% - F6-08), 80%] 
 
Time proportion of S-curve at Decel start 20.0 20.0 
 
 0.0% to Min[(100.0% - F6-27), 80%] 
 
Time proportion of S-curve at Decel end 30.0 30.0 
 
 0.0% to Min[(100.0% - F6-26), 80%] 
Set DC injection for stopping 
DC injection 2 frequency threshold 0.50 0.50 
 
 0.00 Hz to maximum frequency 
 
DC Injection 2 delay ON set time 0.0 0.0 
 
DC injection 2 level 30 30 
 
DC injection 2 active set  time 0.5 0.5 
 
 0.0 to 36.0 Sec 
Set VF parameters 
 0: Linear V/F 
1: Multi-point V/F 
SETTING RANGE: 0 to 11; 
 
 0.0 to 30.0 %; 
NOTE: if it is 0, then auto torque boost is activated, and it is recommended to use auto torque boost. 
Set SVC parameters 
Speed loop proportional gain 1 10 10 
 
Speed loop integral time 1 0.5 0.5 
 
Switchover frequency 1 3.00 3.00 
 
Speed loop proportional gain 2 30 30 
 
Speed loop integral time 2 0.5 0.5 
 
Switchover frequency 2 7.00 7.00 
 
 F2-02 to maximum output frequency