EasyManua.ls Logo

Inovance MD380L - Page 23

Inovance MD380L
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
CONTINUE
Para.
Parameter name Default
Commissioning
Set S-curve
F6-
07
Acceleration/Deceleration mode 3 3
0 : Linear acceleration/ deceleration
3: S-curve acceleration/ deceleration C
F6-
08
Time proportion of S-curve at Accel start 80.0 80.0
0.0% to Min[(100.0% - F6-09), 80%]
F6-
09
Time proportion of S-curve at Accel end 10.0 10.0
0.0% to Min[(100.0% - F6-08), 80%]
F6-
26
Time proportion of S-curve at Decel start 20.0 20.0
0.0% to Min[(100.0% - F6-27), 80%]
F6-
27
Time proportion of S-curve at Decel end 30.0 30.0
0.0% to Min[(100.0% - F6-26), 80%]
Set DC injection for stopping
F6-
11
DC injection 2 frequency threshold 0.50 0.50
0.00 Hz to maximum frequency
F6-
12
DC Injection 2 delay ON set time 0.0 0.0
0.0 to 36.0 Sec
F6-
13
DC injection 2 level 30 30
0 to 100 Hz
F6-
14
DC injection 2 active set time 0.5 0.5
0.0 to 36.0 Sec
Set VF parameters
F3-
00
V/F curve selection 0 0
if it is VF control
0: Linear V/F
1: Multi-point V/F
SETTING RANGE: 0 to 11;
F3-
01
Torque boost 0.0 0.0
0.0 to 30.0 %;
NOTE: if it is 0, then auto torque boost is activated, and it is recommended to use auto torque boost.
Set SVC parameters
F2-
00
Speed loop proportional gain 1 10 10
0 to 100.
F2-
01
Speed loop integral time 1 0.5 0.5
0.01 to 10.00 Sec.
F2-
02
Switchover frequency 1 3.00 3.00
0.00 to F2-05
F2-
03
Speed loop proportional gain 2 30 30
0 to 100.
F2-
04
Speed loop integral time 2 0.5 0.5
0.01 to 10.00 Sec.
F2-
05
Switchover frequency 2 7.00 7.00
F2-02 to maximum output frequency
OVER

Related product manuals