Options
‑110‑
Figure 5‑42 AC output reactor model
Note
● The following recommended AC output reactors are applicable only for T1 to T9
models.
● For T10 to T12 models, purchase AC output reactors with a model number
containing "‑L".
● T13 models are delivered with an AC output reactor.
Table 5–46 Applicable Inovance AC output reactors (three‑phase 380 V to 480 V)
Structure AC Drive Model Reactor Model
Inductance
(mH)
Loss (W)
T1
MD500T0.4G/0.7PB‑PLUS
MD‑OCL‑5‑1.4‑4T‑1% 1.4 ‑
MD500T0.7G/1.1PB‑PLUS
MD‑OCL‑5‑1.4‑4T‑1% 1.4 ‑
MD500T1.1G/1.5PB‑PLUS
MD‑OCL‑5‑1.4‑4T‑1% 1.4 ‑
MD500T1.5G/2.2PB‑PLUS
MD‑OCL‑7‑1.0‑4T‑1% 1.0 ‑
MD500T2.2G/3PB‑PLUS
MD‑OCL‑10‑0.7‑4T‑1% 0.7 ‑
MD500T3.0G/3.7PB‑PLUS
MD‑OCL‑10‑0.7‑4T‑1% 0.7 ‑
T2
MD500T3.7G/5.5PB‑PLUS
MD‑OCL‑15‑0.47‑4T‑1% 0.47 ‑
MD500T5.5G/7.5PB‑PLUS
MD‑OCL‑20‑0.35‑4T‑1% 0.35 ‑
T3
MD500T7.5G/11PB‑PLUS
MD‑OCL‑30‑0.23‑4T‑1% 0.23 ‑
MD500T11G/15PB‑PLUS
MD‑OCL‑40‑0.18‑4T‑1% 0.18 ‑
T4
MD500T15G/18.5PB‑PLUS
MD‑OCL‑40‑0.18‑4T‑1% 0.18 ‑
T5
MD500T18.5G/22P(B)‑PLUS
MD500T18.5G/22P(B)‑T‑PLUS
MD‑OCL‑50‑0.14‑4T‑1% 0.14 ‑
MD500T22G/30P(B)‑PLUS
MD500T22G/30P(B)‑T‑PLUS
MD‑OCL‑60‑0.12‑4T‑1% 0.12 ‑
T6
MD500T30G/37P(B)‑PLUS
MD‑OCL‑80‑0.087‑4T‑1% 0.087 ‑
MD500T37G/45P(B)‑PLUS
MD‑OCL‑120‑0.058‑4T‑1% 0.058 ‑
T7
MD500T45G/55P(B)‑PLUS
MD‑OCL‑120‑0.058‑4T‑1% 0.058 ‑
MD500T55G/75P(B)‑PLUS
MD‑OCL‑150‑0.047‑4T‑1% 0.047 ‑