EasyManua.ls Logo

Inovance MD500-PLUS Series - EMC Filter

Inovance MD500-PLUS Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
‑85‑
Structure Model
Applicable Reactor
Inductance
(mH)
Loss (W)
T13
MD500T500G/630P‑PLUS
MD500T500G/630P‑A‑PLUS
RWK 3044‑1000‑99‑E0XXX 0.029 1167
MD500T560G/710P‑PLUS
MD500T560G/710P‑A‑PLUS
RWK 3044‑1000‑99‑E0XXX 0.029 1167
MD500T630G/800P‑PLUS
MD500T630G/800P‑A‑PLUS
Note: T13 models containing "‑A" in the designation are delivered with an input reactor.
Table 5–25 Recommended specifications of Schaffner AC input reactors (three‑phase 200 V to 240 V)
(Schaffner)
Structure Model
Applicable Reactor
Inductance
(mH)
Loss (W)
T1
MD500‑2T0.4G/0.7PB‑PLUS
RWK 3044‑3.5‑88‑E0XXX 8.3 32
MD500‑2T0.7G/1.1PB‑PLUS
RWK 3044‑6.5‑88‑E0XXX 4.6 47
MD500‑2T1.1G/1.5PB‑PLUS
RWK 3044‑6.5‑88‑E0XXX 4.6 47
MD500‑2T1.5G/2.2PB‑PLUS
RWK 3044‑12‑88‑E0XXX 2.44 69
T2
MD500‑2T2.2G/3.7PB‑PLUS
RWK 3044‑12‑88‑E0XXX 2.44 69
MD500‑2T3.7G/5.5PB‑PLUS
RWK 3044‑18‑89‑E0XXX 1.67 103
T3
MD500‑2T5.5G/7.5PB‑PLUS
RWK 3044‑35‑92‑E0XXX 0.83 151
T4
MD500‑2T7.5G/11PB‑PLUS
RWK 3044‑48‑92‑E0XXX 0.61 172
T5
MD500‑2T11G/15P(B)‑PLUS
RWK 3044‑59‑92‑E0XXX 0.5 206
T6
MD500‑2T15G/18.5P(B)‑PLUS
RWK 3044‑59‑92‑E0XXX 0.5 206
MD500‑2T18.5G/22P(B)‑PLUS
RWK 3044‑72‑99‑E0XXX 0.41 294
T7
MD500‑2T22G/30P(B)‑PLUS
RWK 3044‑59‑92‑E0XXX 0.5 206
MD500‑2T30G/37P(B)‑PLUS
RWK 3044‑120‑99‑E0XXX 0.24 324
T8
MD500‑2T37G/45P(B)‑PLUS
RWK 3044‑140‑99‑E0XXX 0.2 399
MD500‑2T45G/55P‑PLUS
RWK 3044‑180‑99‑E0XXX 0.17 456
MD500‑2T55G/75P‑PLUS
RWK 3044‑210‑99‑E0XXX 0.14 553
T9
MD500‑2T75G/90P‑PLUS
RWK 3044‑320‑99‑E0XXX 0.092 747
T10
MD500‑2T90G/110P‑PLUS
RWK 3044‑400‑99‑E0XXX 0.073 1055
MD500‑2T110G/132P‑PLUS
RWK 3044‑510‑99‑E0XXX 0.058 1069
T11
MD500‑2T132G/160P‑PLUS
RWK 3044‑510‑99‑E0XXX 0.058 1069
T12
MD500‑2T160G/200P‑PLUS
RWK 3044‑570‑99‑E0XXX 0.052 1181
MD500‑2T200G/220P‑PLUS
RWK 3044‑800‑99‑E0XXX 0.037 1280
5.4.3 EMC Filter
Overview
To meet the conducted and radiated emission requirements of EN IEC 61800‑3, the AC
drive must be connected to an external EMC filter listed in the following table.

Table of Contents

Other manuals for Inovance MD500-PLUS Series

Related product manuals