‑121‑
Figure 5‑50 Dimension drawing of output reactors (4 A to 45 A)
Table 5–59 Mounting dimensions of output reactors (4 A to 45 A) (unit: mm)
Rated
Current
A B C D E F G
4 A and 7.8 A 100 Max. 60 max.115 56 34 4.8 x 9 2.5 mm
2
10 A 100 max.70 max.115 56 43 4.8 x 9 2.5 mm
2
14 A 125 max.70 max.135 100 45 5 x 8 2.5 mm
2
17 A 125 max.75 max.135 100 55 5 x 8 2.5 mm
2
24 A 125 max.75 max.135 100 55 5 x 8 4 mm
2
32 A 155 max.95 max.170 130 56 8 x 12 10 mm
2
45 A 155 max.110 max.190 130 72 8 x 12 10 mm
2