Chapter 2 Installation and Wiring
-
24
-
Type
Terminal
Symbol
Terminal
Name
Function Description Remark
Power/
Communication
terminal (CN3)
BIT0
Fault binary
code
It outputs the current fault code
using the 8421 code and can
be connected to the external
LED display.
It supports both common anode
LED display and common
cathode LED display.
A common relay is
used.
BIT1
BIT2
BIT3
BM
Common
terminal
Interface for
operation
panel (J11)
RJ45
Interface for
the operation
panel
It is connected to the operation
panel for modify ing parameters
or viewing the status.
-
NOTE
If there is no auxiliary brake in the system, short X8 and X9 to DC-.
If the floor plate switches in the system have the compulsory break-off
function, the related function of this system can be disabled. In this case,