Jumper Blocks Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
102 Revision 1.1
Intel order number G34153-003
6. Power down the server.
7. Open the chassis and move the jumper back to its default position (covering pins 1 and
2).
8. Close the server chassis.
9. Power up the server.
The password is now cleared and you can reset it by going into the BIOS setup.
7.2 Force BMC Update Procedure
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event the BMC firmware update process fails due to the BMC not being in the proper
update state, the server boards provide a Force BMC Update jumper that forces the BMC into
the proper update state. In the event the standard BMC firmware update process fails, complete
the following procedure:
1. Power down and remove the AC power cord.
2. Open the server chassis. See your server chassis documentation for instructions.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the
enabled position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC power cord and power up the server.
6. Perform the BMC firmware update procedure as documented in the BMC firmware
update package. After successful completion of the firmware update process, the
firmware update utility may generate an error stating the BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC power cord and power up the server.
Note: When the Force BMC Update jumper is set to the enabled position, normal BMC
functionality is disabled. You should never run the server with the Force BMC Update jumper
set in this position. You should only use this jumper setting when the standard firmware update
process fails. When the server is running normally, this jumper must remain in the
default/disabled position.
7.3 BIOS Recovery Jumper
The following procedure boots the recovery BIOS and flashes the normal BIOS:
1. Turn off the system power.
2. Move the BIOS recovery jumper to the recovery state.

Table of Contents

Other manuals for Intel S1400SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1400SP and is the answer not in the manual?

Intel S1400SP Specifications

General IconGeneral
BrandIntel
ModelS1400SP
CategoryMotherboard
LanguageEnglish

Related product manuals