EasyManuals Logo
Home>Intel>Motherboard>S1400SP

Intel S1400SP User Manual

Intel S1400SP
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor
Tables
Revision 1.1
Intel order number G34153-003
125
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
05 - Non-
redundant:
insufficient
resources
Fatal
06 Redundant:
degraded from
fully redundant
state.
Degraded
07 Redundant:
Transition from
non-redundant
state.
Degraded
IPMI Watchdog
(IPMI
Watchdog)
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
OK
As
Trig
Offset
A
X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer
interrupt
Physical
Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
Degraded
OK
As and De
Trig
Offset
A
X
04 - LAN leash
lost
FP Interrupt
(FP NMI Diag
Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK
As
Trig
Offset
A
SMI Timeout
(SMI Timeout)
06h
All
SMI Timeout
F3h
Digital Discrete
03h
01 State
asserted
Fatal
As and De
Trig
Offset
A

Table of Contents

Other manuals for Intel S1400SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1400SP and is the answer not in the manual?

Intel S1400SP Specifications

General IconGeneral
BrandIntel
ModelS1400SP
CategoryMotherboard
LanguageEnglish

Related product manuals