Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
128
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
System Airflow
(System
Airflow)
11h
All
Other Units
0Bh
Threshold
01h
Analog
FW Update
Status
12h
All
Version
Change 2Bh
OEM defined
x70h
00hUpdate
started
01hUpdate
completed
successfully.
02hUpdate
failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13h
Platform-
specific
Module/Board
15h
Digital Discrete
08h
01
Inserted/Present
OK
As and De
Trig
Offset
M
-
Baseboard
Temperature 5
(Platform
Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Baseboard
Temperature 6
(Platform
Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
IO Module2
Temperature
(I/O Mod2
Temp)
16h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
PCI Riser 3
Temperature
(PCI Riser 5
Temp)
17h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X

Table of Contents

Other manuals for Intel S1400SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1400SP and is the answer not in the manual?

Intel S1400SP Specifications

General IconGeneral
BrandIntel
ModelS1400SP
CategoryMotherboard
LanguageEnglish

Related product manuals