39
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 510 + ENTER 8 + ENTER
Note:
»
Enables the xation of triggered events to
be cleared even when the system is activa-
ted by Remote Control.
»
Factory Default: Disabled.
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 516 + ENTER 3 + ENTER
Note:
»
The siren will emit 1 beep upon activation
and 2 beeps upon deactivation by Remote
Control only.
»
Factory Default: Enabled.
ENTER + 516 + ENTER 4 + ENTER
Note:
»
The siren will emit 1 beep upon activation and
2 beeps upon deactivation by Keyboard only.
»
Factory Default: Enabled.
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 511 + ENTER 1 + ENTER
Note:
»
Pressing the 0 key for 3 seconds will generate
the silent panic event.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 2 + ENTER
Note:
»
Pressing Key 2 for 3 seconds will generate the
audible panic event.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 3 + ENTER
Note:
»
Pressing the 5 key for 3 seconds will generate
the medical emergency event.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 4 + ENTER
Note:
»
Pressing the 8 key for 3 seconds will generate
the re event.
»
Factory Default: Disabled
.
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 511 + ENTER 5 + ENTER
Note:
»
Pressing the 3 key for 3 seconds will genera-
te the maintenance event.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 6 + ENTER
Note:
»
The keyboard display backlight will always
stay on.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 7 + ENTER
Note:
»
If the functions Trouble indication by siren
and Siren beep on Activation/Deactivation
are enabled. If any trouble is detected, 4
short beeps will be emitted upon activation
and 2 short beeps will be emitted upon
deactivation.
»
Factory Default: Disabled.
ENTER + 511 + ENTER 8 + ENTER
Note:
»
The cancellation becomes by the number of
times the zone is opened.
»
Factory Default: Enabled.