40
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 512 + ENTER 1 + ENTER
Note:
»
Blocks all kinds of Reset.
»
Factory Default: Disabled.
ENTER + 512 + ENTER 2 + ENTER
Note:
»
Blocks the Remote Controls. Activation /
Deactivation by password only.
»
Factory Default: Disabled.
ENTER + 512 + ENTER 3 + ENTER
Note:
»
Keyboard will be locked for 10 minutes after
the 4th attempt of access by password. It will
send a Wrong Password notication to the
monitoring company.
»
Factory Default: Disabled.
ENTER + 512 + ENTER 4 + ENTER
Note:
»
Blocks Activation/Deactivation via telephone.
»
Factory Default: Disabled.
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 512 + ENTER 5 + ENTER
Note:
»
It will send, at the moment it occurs, a
trouble event.
»
Factory Default: Enabled.
ENTER + 512 + ENTER 6 + ENTER
Note:
»
Use this function when you have sensors
from another manufacturer or Intelbras
1000 series sensors, which do not have
Low Battery detection.
»
Factory Default: Disabled.
ENTER + 512 + ENTER 7 + ENTER
Note:
»
It will display the clock when all Zones are
closed. Otherwise it will show on the dis-
play the Zones that are open.
»
Factory Default: Disabled.
ENTER + 512 + ENTER 8 + ENTER
Note:
»
In the event of a power failure, the battery
will be used until it is completely drained.
»
Factory Default: Enabled.
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 513 + ENTER 1 + ENTER
Note:
»
For siren wire cut detection, a 2k2 resis-
tor must be connected in parallel with
the siren.
»
Factory Default: Disabled.
ENTER + 513 + ENTER 2 + ENTER
Note:
»
It will send a Siren Trouble event, if the siren
wire is short-circuited.
»
Factory Default: Disabled.
ENTER + 513 + ENTER 3 + ENTER
Note:
»
Triggers the siren, even if the system is
deactivated.
»
Factory Default: Disabled.
ENTER + 513 + ENTER 8 + ENTER
Note:
»
Hides the editable message on the key-
board.
»
Factory Default: Disabled.