41
Sensor Battery Test
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 79 + ENTER
Note:
»
Battery is ok= 3 short beeps.
»
Low Battery= 1 long beep.
Sensor Test
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 52 + ENTER
Note:
»
When enabled, the siren beeps 1 time whenever
a sensor is opened or closed.
Remote Control for Medical Emergencies
Settings Result
Register
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 65 +
ENTER
Control Key
actuation
Note:
»
Registered Control= 3 short beeps.
»
Control Not Registered = 1 long beep.
Delete
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 75 +
ENTER
Note:
»
Deletes all devices registered as Remote
Control for Medical Emergencies.
Automatic Zone Cancellation
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 53 + Trigger N.
+ ENTER
Note:
»
Trigger Number: 0 to 9.
»
Factory default: 0.
Keyboard Message editing
Settings Result
Note: keyboard message editing is available up to version 4.70 of amt 2018 e/eg. Above this
version, message editing must be done by amt remote or amt remote app. amt 2118 eg and amt
2018 e3G have keyboard message editing in all versions.
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 1 + ACTIVATE +
00 + ENTER
TYPE NAME + ENTER
Note:
»
Type the Center’s Name.
»
NAME: Up to 14 characters.
»
Factory default: Intelbras.
ENTER + 1 + ACTIVATE +
00 + ENTER
TYPE NAME + ENTER
Note:
»
Type a Name for the Users.
»
NAME: Up to 14 characters.