Starting Dual Antenna System
55
6. Try to access the LUI again using the changed Compound UT#2 (Secondary) ip address
(192.168.100.10).
7. Go to Diagnostics → Compound UT Info to verify the
Secondary
of CUC (Compound UT Controller)
role on the Compound UT Info.
NOTE
If you cannot see “Compound UT Info” menu on “Diagnostics” in the 6th step, check the CUC role’s settings
and try to start the first process again.
7.2.2 Setting the Compound UT#1 (Primary)
The Compound UT#1 (Primary) should be set after setting the Compound UT#2 (Secondary).
1. Turn on the UT#1’s POWER switch on the front panel of the CNX, and then wait a few seconds for
system startup. The MoCA indicator light on the CNX display will turn green.
Power On/Off
Switch
MoCA
indicator
NOTE
If the MoCA indicator does not turn on after five minutes during step 1, check the cable connection status
and try to turn the CNX power off and on again.
2. Use the following IP address to access the LUI page.
• IP Address: 192.168.100.1 (Default)
NOTE
The
LUI
should be accessed by Chrome web browser when setting a CUC (Compound UT Controller) role.
3. Select Install on the navigation bar, and then go to the Installation Navigation.
4. Press Back or Next button on the Installation Navigation until the Select Installation Role reach.