35
IMPORTANT
The air supply duct in the façade must
have an Intergas intake grille (item no
926187).
The individual flue pipe (Ø80) must be
constructed of stainless steel or plastic
PP T120.
min. 500
Allowed pipeline length
Air supply duct and flue pipe, including the length of the
terminal.
Boiler Length
Intergas Xtreme 24 100 m
Intergas Xtreme 30 85 m
Intergas Xtreme 36 80 m
Assembly of vertical flue terminal
On a steep roof, install a weather slate
with scale at the location of the terminal.
On a flat roof, install a weather slate for a double-walled
terminal Ø80 mm (diameter Ø96 mm).
Slide the double-walled terminal from the
outside to the inside through the roof terminal.
The terminal must be at least 500mm above the roof
surface.
Assembly of horizontal air supply duct
The air supply can be made in an arbitrary location in the
façade.
At the location of the supply, make an opening of Ø90 mm.
Shorten the air supply duct pipe to the desired length out of
the wall.
Install the Intergas intake grille and attach this to the pipe.
Slide the air supply duct pipe in the opening and cover the
opening, if necessary, with a rosette.
Install the air supply duct, at the location of the façade
terminal, to the exterior at an angle directed outside to
prevent rain entering.
6.8.4 Roof terminal and air supply duct from the
façade C53
Flue through a prefab chimney or through a double-walled
roof terminal Ø80 mm with pulling exhaust cap.
The prefab chimney must have flue openings of at least
150cm
2
per connected boiler and must satisfy the indicated
minimum measurements. The supplier of the prefab chimney
must guarantee the correct operation of the chimney in terms
of wind exposure, ice formation, rain entering, recirculation etc.
Intergas intake grille