The FT Series Floor Standing, Heating Only Boiler
Page 11
Carbon monoxide poisoning
If vent pipe fumes enter the room, it could cause
poisoning by carbon monoxide gas. Check that the
vent pipes are properly connected. Open windows
for ventilation. Call a qualied service technician for
immediate repair.
Gas leakage test.
Gas supply line must be inspected regularly.
Do not shut o󰀨 the Boiler.
When you leave home for a long time, do not shut o󰀨
Boiler. The Boiler has a freeze protection function.
Do not wipe the appliance or control panel with wet
cloth. Electric shock may occur, or internal parts may
fail due to the exposure to moisture.
Do not disassemble the Boiler.
If repair is required, call your local qualied technician.
Before Operation
1. Check the Gas Type (NG/LP) when using or
moving the unit for the rst time. Check if gas type
matches with the gas type of the boiler. Check
whether the gas type which is supplied is NG
(Natural Gas) or LP (Propane) and also check the
boiler gas type. The gas type is indicated on the
rating plate on side of the Boiler.
2. Check the Power (120V 60Hz). Check that the
appliance is connected properly.
3. Check the Cold Water Inlet valve. Please keep the
appliance water inlet valve open at all times. The
appliance will not ignite when insu󰀩cient water
or no water is in the heating pipes. (valve: always
open position)
4. Check the manual gas shut-o󰀨 valve on top of the
FT boiler gas connection. Make sure this manual
gas shut-o󰀨 valve is opened for operation.
5. Check the area around the appliance and remove
any combustible or ammable materials. Remove
laundry or any other items that are on or near the
boiler or vent pipe.
When in Operation
CAUTION
1. Caution for gas leak
Frequently check for a gas leak at the gas connection
portion with soapy water.
Steps to take if you have a gas leak.
1. Shut down the boiler as soon as gas fumes are
detected.
2. Close the manual gas shut-o󰀨 valve.
3. Open windows for ventilation.
4. Do not create any sparks! Leave the property
immediately and call your local utility or qualied
service technician for immediate repair.
2. Caution for Ventilation
Make sure that there is su󰀩cient inow and outow of air
ventilation while using the unit.
If the ventilation is improper, combustion quality may
deteriorate inside the appliance and cause shortened life
of the appliance.
3. Burn Warning
Be careful not to burn yourself on the ue or pipes. They
become extremely hot during operation.
CAUTION
Scalding Risk: Manufacturer strongly recommends the
use of an anti-scald mixing valve at domestic hot water
outlet (indirect tank location) to reduce potential for
scalding. Check with local codes.
__________________________________________
CAUTION
After repair of gas pipeline or gas regulator replacement,
call a qualied contractor for inspection before starting it up.
__________________________________________
Do not use the appliance for any other purpose than
for heating and hot water.
Do not store combustibles or ammable material
such as gasoline near the appliance.
Do not store other items on or near this boiler.
Do not store combustible (ammable) materials
such as papers.
Do not hang clothes on the vent pipe. This may
start a re.
WARNING