EasyManua.ls Logo

Intertek FT Series - SECTION 8 Maintenance; Annual Startup & General Maintenance

Default Icon
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The FT Series Floor Standing, Heating Only Boiler
Page 79
Regular Maintenance
- This Manual should be placed in a safe and dry
location near the boiler. Maintenance instructions
should be carried out by the following guidelines.
Maintenance procedures [ Daily ]
- Check that the boiler front cover is closed.
The front cover must be installed with both top
latches tightened while the boiler is in operation.
- Check the power source.
Make sure that the power cord is correctly connected.
The main power line is connected to the manual
switch box inside the boiler. (Power line through the
strain relief in the top of the boiler casing and x it.)
- Check the status of the control panel
Check status of the power supply. Please check for
any debris on the button.
Maintenance procedures [ Monthly ]
- Check the vent pipe.
Visually inspect the ue gas vent piping for detecting
any signs of blockage, leakage or deterioration of the
piping. Please contact a qualied service technician
immediately if you nd any problem.
- Check the air inlet pipe.
Visually inspect the air inlet piping and combustion.
Inspect entire length of air piping for ensuring that
piping is intact and all joints are properly sealed. To
remove the combustion air lter (located on the left
pipe), remove 2 holding screws and carefully slide
out lter assembly. Clean throroughly and put back
in. Make sure no debvris fell into the boiler. Call your
qualied service technician if you notice any problems.
- Check the relief valve.
Inspect the boiler relief valve and the relief valve
discharge pipe for any signs of weeping or leakage.
If the relief valve often weeps, immediately contact
your qualied service technician for inspecting the
Combination boiler and system.
- Check the condensate outlet.
While the boiler is running, check the discharge end
of the condensate drain tubing. Make sure that no ue
gas is escaping from the condensate drain tubing.
If ue gas is continuously escaping, it is a serious
problem. Shut o󰀨 the boiler and immediately. Call your
qualied service technician for inspecting the boiler
and condensate line. Also, rell the condensate trap if
problem persists regularly.
- Check the vent terminal screen vent (rodent
screen).
If you encounter a problem of combustion
performance, visually inspect the terminal screen.
And then replace it with spare parts or clean the
screens.
SECTION 8 Maintenance
8.1 Annual startup &
general maintenance
WARNING
WARNING
To prevent potential severe personal
injury, death or substantial property
damage, remove all contaminates or
contaminated materials immediately
from the area around the boiler.
If exposed to contaminated materials,
call a qualied service technician to
inspect the boiler for possible damage
from acid corrosion.
DO NOT store combustible materials,
gasoline or any other ammable vapors
or liquids near the Boiler. Remove them
immediately or store them other places.

Table of Contents