OPERATING METHODS
Location Requirements Of The temp. range of this unit is
the Unit 16° C - 30°C
Unit Setup Place the unit on horizontal floor when using and maintain a
distance for above 50cm from walls, surface of flammable
objects or other obstructions.
Power Check before connecting power:
The normal running fluctuation range of voltage of the unit is
It is better to adopt power lead with pickup current above 10A to
prevent sudden drop of voltage when the unit is running.
It is necessary to exchange broken power hose by special
power hose. When it is necessary to change power hose or
maintain, please contact the seller and have them repaired by
professional personnel.
Earth must be conducted reliably and should connect to special
earthing equipments in building to ensure well earth.
Do not replace fuse by steel or copper and capacity for fuse
should be proper. It is forbidden to fix power on blade or sharp
objects to prevent creepage leaded by mangled wire.
Circuitry must be installed and fixed by professional personnel
following the national wiring regulations. Creepage protect
switch with enough capacity and 10A solenoid heat tripping air
switch must be contained in circuitry. It is forbidden to connect
earth wire to water pipe or gas pipe, plug off power plug or cut
off power supply when the unit is not going to be used.
6