43
Parameter Access Tables
www.invertekdrives.com
Optidrive P2 Advanced User Guide Revision 2.00
Parameter
Number
R/W
Modbus
RTU
Register
Number
CAN
Open
Index
CAN
Open
Sub
Index
Profibus
DP
DeviceNet
EtherNet
IP
EtherCAT
Modbus
TCP
Profinet
IO
Parameter Name
Setting Range
Scaling
Type
P2-33
R/W
233
20E9h
0h
0, 232
A2h, 233, X
A2h, 233, X
20E9h
760
0, 0, 1, 00E9h
Analog input 2 format
0 = 0-10V
1 = Ptc-th
2 = 0-20mA
3 = t 4-20mA
4 = r 4-20mA
5 = t 20-4mA
6 = r 20-4mA
U16
P2-34
R/W
234
20EAh
0h
0, 233
A2h, 234, X
A2h, 234, X
20EAh
761
0, 0, 1, 00EAh
Analog input 2 scaling
0 to 5000
1 = 0.1
U16
P2-35
R/W
235
20EBh
0h
0, 234
A2h, 235, X
A2h, 235, X
20EBh
762
0, 0, 1, 00EBh
Analog input 2 offset
-5000 to 5000
1 = 0.1
S16
P2-36
R/W
236
20ECh
0h
0, 235
A2h, 236, X
A2h, 236, X
20ECh
763
0, 0, 1, 00ECh
Start mode select
0 = Edge-r
1 = Auto-0
2 = Auto-1
3 = Auto-2
4 = Auto-3
5 = Auto-4
6 = Auto-5
U16
P2-37
R/W
237
20EDh
0h
0, 236
A2h, 237, X
A2h, 237, X
20EDh
764
0, 0, 1, 00EDh
Keypad restart speed
0: Minimum speed
1: Previous keypad speed
2: Current running Speed
3: Preset Speed 8
U16
P2-38
R/W
238
20EEh
0h
0, 237
A2h, 238, X
A2h, 238, X
20EEh
765
0, 0, 1, 00EEh
Mains loss stop control
0: Mains loss ride through
1: Coast to Stop
2: Fast ramp to stop
U16
P2-39
R/W
239
20EFh
0h
0, 238
A2h, 239, X
A2h, 239, X
20EFh
766
0, 0, 1, 00EFh
Parameter Lock
0: Unlocked
1: Locked
WORD
P2-40
R/W
240
20F0h
0h
0, 239
A2h, 240, X
A2h, 240, X
20F0h
767
0, 0, 1, 00F0h
Extended parameter access code
definition
0 ... 9 999
U16