Do you have a question about the Invertek optidrive cp2 and is the answer not in the manual?
Details the arrangement of parameters into groups and their access levels.
Lists and describes basic parameters like frequency limits and ramp times.
Selects the motor control method (e.g., Vector, V/F).
Selects the main control source and primary speed reference.
Selects pre-assigned functions for digital inputs.
Lists available switching frequencies by drive model and rating.
Access tables for basic parameter group 1 across various protocols.
Access tables for extended parameter group 2 across protocols.
Access tables for PID control parameters across protocols.
Access tables for motor control parameters across protocols.
Explains how the drive manages heatsink temperatures.
De-rating curves for Size 2, 200-240V drives.
Lists input/output current ratings by frame size and voltage.
Describes the specifications for digital and analog inputs/outputs.
Explains the output current limit and overload operation.
Details the trip levels for under and over voltage conditions.
Details the arrangement of parameters into groups and their access levels.
Lists and describes basic parameters like frequency limits and ramp times.
Selects the motor control method (e.g., Vector, V/F).
Selects the main control source and primary speed reference.
Selects pre-assigned functions for digital inputs.
Lists available switching frequencies by drive model and rating.
Access tables for basic parameter group 1 across various protocols.
Access tables for extended parameter group 2 across protocols.
Access tables for PID control parameters across protocols.
Access tables for motor control parameters across protocols.
Explains how the drive manages heatsink temperatures.
De-rating curves for Size 2, 200-240V drives.
Lists input/output current ratings by frame size and voltage.
Describes the specifications for digital and analog inputs/outputs.
Explains the output current limit and overload operation.
Details the trip levels for under and over voltage conditions.
| Enclosure Rating | IP20 |
|---|---|
| Overload Capacity | 150% for 60 seconds |
| Output Current | Varies by model (refer to specific model datasheet) |
| Communication Protocols | Modbus RTU |
| Dimensions | Varies by model (refer to specific model datasheet) |
| Braking | Built-in dynamic braking (optional external braking resistor) |
| Protection Features | Overcurrent, overvoltage, undervoltage, short circuit, overheating, phase loss |
| Operating Temperature | -10°C to +40°C |
| Weight | Varies by model (refer to specific model datasheet) |