EasyManua.ls Logo

Invertek optidrive cp2 User Manual

Invertek optidrive cp2
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AC Variable Speed Drive
0.75kW 250kW / 1HP 350HP
200 480 Volt 1 & 3 Phase
Advanced User Guide
Revision 2.00
Question and Answer IconNeed help?

Do you have a question about the Invertek optidrive cp2 and is the answer not in the manual?

Invertek optidrive cp2 Specifications

General IconGeneral
BrandInvertek
Modeloptidrive cp2
CategoryServo Drives
LanguageEnglish

Summary

Advanced User Guide

1. Optidrive P2 Parameter Set Overview

1.2. Parameter Structure Overview

Details the arrangement of parameters into groups and their access levels.

1.3. Parameter Descriptions

1.3.1. Parameter Group 1 - Basic Parameters

Lists and describes basic parameters like frequency limits and ramp times.

1.3.2. Parameter Group 2 - Extended parameters

1.3.3. Parameter Group 3 – PID Control

1.3.4. Parameter Group 4 - High Performance Motor Control

P4-01 Motor Control Mode

Selects the motor control method (e.g., Vector, V/F).

1.3.6. Parameter Group 6 - Advanced Functions

1.3.7. Parameter Group 7 - Motor Data

1.4. Parameter Group 9 – Programmable Logic Functions

1.7. Control Terminal Connections

1.7.1. P1-12 Function

Selects the main control source and primary speed reference.

1.7.2. P1-13 Function

Selects pre-assigned functions for digital inputs.

2. Drive Model Specific Parameter Variations

2.1. Available Effective Switching Frequency Options

Lists available switching frequencies by drive model and rating.

4. Fieldbus Interface Support

4.7. Parameter Access Tables

4.7.1. Group 1: Basic Parameter Set (Level 1)

Access tables for basic parameter group 1 across various protocols.

4.7.2. Group 2: Extended parameter set (Level 2)

Access tables for extended parameter group 2 across protocols.

4.7.3. Group 3: User PID control (Level 2)

Access tables for PID control parameters across protocols.

4.7.4. Group 4: Motor control parameter set (Level 2)

Access tables for motor control parameters across protocols.

5. Diagnostic and Fault Messages

6. Rated Temperatures and De-rating curves

6.1. Thermal Management

Explains how the drive manages heatsink temperatures.

6.3. Size 2, 200-240V

De-rating curves for Size 2, 200-240V drives.

7. Immunity Tests

8. General Technical and Performance Data

8.2. Input Output Current Ratings

Lists input/output current ratings by frame size and voltage.

8.6. Digital & Analog I/O

Describes the specifications for digital and analog inputs/outputs.

8.10. Output Current Limit

Explains the output current limit and overload operation.

8.11. Under / Over Voltage Trip Levels

Details the trip levels for under and over voltage conditions.