Goodrive170-PV Series Solar Pump Inverter Function parameter list
-48-
Present
inductive
current
It is transferred from the boost module, and
valid only in AC mode and invalid in PV
mode.
Device
configurati
on display
0x00–0x11
LED ones place:
0: PV power supply
1: AC grid power supply
LED tens place:
0: Detect that the system is configured with
the boost module.
1: Detect that the system is not configured
with the boost module.
High-order
bits in total
pump flow
Used to display the 16 high-order bits of the
total pump flow. Unit: cubic meter.
Low-order
bits in total
pump flow
Used to display the 16 low-order bits of the
total pump flow. Unit: cubic meter.
Total pump flow = P18.13*65535 + P18.14
When it is set to 1, the total pump flow can
be reset. P18.13 and P18.14 are cleared
and then accumulated again. After the
resetting succeeds, P18.15 is automatically
changed to 0.