Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-152-
Function
code
Name
Description
Default
value
Modify
FWD
REV
COM
Sln
SB2
SB1
SB3
Sln
FWD
REV
Running
direction
ON
OFF→ON
ON
Forward
OFF
Forward
ON
ON
OFF→ON
Reverse
OFF
Reverse
ON→OFF
/
/
Decelerate
to stop
/
/
Sln: 3-wire control, FWD: Forward running, REV:
Reverse running
Note: For dual-line running mode, when
FWD/REV terminal is valid, if the VFD stops due to
stop command given by other sources, it will not
run again after the stop command disappears
even if the control terminals FWD/REV are still
valid. To make the VFD run again, users need to
trigger FWD/REV again, eg, PLC single-cycle
stop, fixed-length stop, and valid STOP/RST stop
during terminal control. (see P07.04).
P05.12
S1 terminal
switch-on
delay
These function codes define corresponding delay
of the programmable input terminals during level
variation from switch-on to switch-off.
Si electrical level
Si valid
invalid invalid
Switcn-on
delay
Switcn-off
delay
valid
Setting range: 0.00050.000s.
Note: After a virtual terminal is enabled, the state
of the terminal can only be changed in
communication mode. The communication
address is 0x200A.
0.000s
P05.13
S1 terminal
switch-off
delay
0.000s
P05.14
S2 terminal
switch-on
delay
0.000s
P05.15
S2 terminal
switch-off
delay
0.000s
P05.16
S3 terminal
switch-on
delay
0.000s
P05.17
S3 terminal
switch-off
delay
0.000s