Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-243-
Function
code
Name
Description
Default
value
Modify
P92.07
Conversion time
from final zero
bit to initial zero
bit
0.0060.00s
5.00s
P92.08
Feeding interrupt
detection mode
03
0: Not detect
1: Detect based on digital value
2: Detect based on roll diameter calculation
value
3: Detect based on feedback position
0
P92.09
Feeding interrupt
detection start
delay time
0.0200.0s
20.0s
P92.10
Frequency lower
limit of feeding
interrupt
detection
0.00300.00Hz
10.00 Hz
P92.11
Error range of
feeding interrupt
detection
0.150.0%
10.0%
P92.12
Determination
delay time of
feeding interrupt
detection
0.160.0s
1.0s
P92.13
Handling mode
of feeding
interrupt
0x0000x111
Ones place: Stop mode
0: Decelerate to stop in emergency manner
1: Coast to stop
Tens place: Alarm mode
0: Stop in enabled stop mode without reporting
an alarm
1: Report an alarm and coast to stop
Hundreds place: Roll diameter memory function
of feeding interrupt
0: Disable
1: Enable
0x000
P92.14
Stop braking
frequency
0.00300.00Hz
1.50Hz
P92.15
Stop braking
time
0.0600.0s
0.0s
P93––Tension control status viewing
Function
code
Name
Description
Default
value
Modify
P93.00
Actual control
mode
03
0: Invalid tension control
1: Close-loop tension speed control
0

Table of Contents