Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-192-
Function
code
Name
Description
Default
value
Modify
0: Communication password protection is invalid
1: Communication password protection is valid
Hundreds place: Valid only for RS485
communication
0: User-defined addresses specified by P14.07
and P14.08 are invalid
1: User-defined addresses specified by P14.07
and P14.08 are valid
P14.07
User-defined
running
command
address
0x00000xFFFF
0x2000
P14.08
User-defined
frequency
setting address
0x00000xFFFF
0x2001
P14.09
Modbus TCP
communication
timeout time
0.060.0s
5.0
P14.10
Enabling
program
upgrade through
RS485
01
0: Disable
1: Enable
0
P14.11
Bootloader
software version
0.00655.35
0.00
P14.12
Displaying no
upgrade
bootloader fault
01
0: Display
1: Do not display
0
P14.13
P14.47
Reserved
/
/
/
P14.48
Channel
selection for
mapping
between PZDs
and function
codes
0x000x12
Ones place: Channel for mapping function
codes to PZDs
0: Reserved
1: Group P15
2: Group P16
Tens place: Save function at power failure
0: Disable
1: Enable
0x12
P14.49
Mapped function
code of received
PZD2
0x00000xFFFF
0x0000
P14.50
Mapped function
code of received
PZD3
0x00000xFFFF
0x0000
P14.51
Mapped function
code of received
0x00000xFFFF
0x0000

Table of Contents