Iris Technology Operator's Manual
QuietPower 1800 (QP-1800) Doc 287.F701 / 100412
Page 39 of 56 Rev 12 APR 2010
5.3 NATO Cable Replacement
The following paragraphs detail the procedure to replace the NATO Cable for connection to the
inverter and the vehicle.
5.3.1 NATO Cable Removal
Remove the NATO Cable from the inverter and the vehicle as follows:
WARNING
MAKE SURE INVERTER IS ELECTRICALLY DISCONNECTED FROM 24
VDC POWER SOURCE (NATO PLUG) PRIOR TO SERVICING. FAILURE
TO DISCONNECT CABLE FROM 24 VDC POWER SOURCE (NATO PLUG)
FIRST MAY RESULT IN FIRE, SEVERE ELECTRIC SHOCK, OR DEATH.
1. Make sure inverter power switch on control panel is in off ('O') position.
2. Disconnect cable from 24 VDC power source.
3. Remove nuts and lock washers securing NATO Cable to inverter.
4. Remove NATO Cable from inverter and from vehicle.