Technical Specification
CR mode(CC Priority
mode)
Range
0.6-1000Ω
Resolution Min.0.1Ω
Accuracy
Rmin(Vreal-Vmax*0.1%)/Rset -Im-
ax*0.2% Rmax(Vreal+Vmax*0.1%)/
Rset +Imax*0.2%
Output Read-back
Read-back current
Range
-30A~30A
Resolution 1mA
Accuracy
≤0.1%+0.1%FS
Read-back Voltage
Range
0-60V
Resolution 1mV
Accuracy
<0.1% Umax
Read-back Power
Range
-200W~200W
Resolution 0.1W
Accuracy
<1% Pmax
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature Coefficient 100ppm/℃
Current Temperature Coefficient 50ppm/℃
Battery Test
AH Measurement
AH Range
0AH-300AH
Accuracy
0.20%
Resolution 0.001AH
Regulation
Load Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Line Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Ripple
Ripple
Voltage ≤100mVp-p
Current ≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
5ms
Rise time
Voltage(Full load)
10ms
Fall time
Voltage(No load)
5ms
Fall time
Voltage(Full load)
5ms
Transient Response
Time
Voltage
≤2mS
Copyright © Itech Electronic Co., Ltd.
109

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals