EasyManua.ls Logo

ITech IT-M3400 Series

ITech IT-M3400 Series
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
11.8 IT-M3424
Parameter IT3424 V1.2
Source Parameter
Rated value
( 0 ℃-40
℃)
Output Voltage
0-300V
Output Current
-6A~6A
Output Power
-400W~400W
Min. operating voltage
30V at -6A
CC
Range
-6A~6A
Setup Resolution
1mA
Accuracy
≤0.1%+0.1%FS
CV
Range
0-300V
Setup Resolution
10mV
Accuracy
<0.1% Umax
Output
Resistance
Range
0-1000mΩ
Internal
Resistance
(CV Prior-
ity mode)
Setup Resolution
0.1mΩ
Accuracy
2%*Rmax
CP
Range
-400W~400W
Setup Resolution
0.1W
Accuracy
<1.0% Pmax
CR mode(CC
Priority
mode)
Range
5-1000Ω
Resolution Min.0.1Ω
Accuracy
Rmin(Vreal-Vmax*0.1%)/Rset -Imax*0.2% Rmax
(Vreal+Vmax*0.1%)/Rset +Imax*0.2%
Output Read-back
Read-back
current
Range
-6A~6A
Resolution 0.1mA
Accuracy
≤0.1%+0.1%FS
Read-back
Voltage
Range
0-300V
Resolution 10mV
Accuracy
<0.1% Umax
Read-back
Power
Range
-400W~400W
Resolution 0.1W
Accuracy
<1% Pmax
Copyright © Itech Electronic Co., Ltd.