EasyManua.ls Logo

ITech IT-M3400 Series

ITech IT-M3400 Series
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
11.2 IT-M3422
Parameter IT-M3422 V1.2
Rated value( 0 ℃-40
℃)
Output Voltage
0-60V
Output Current
-30A~30A
Output Power
-400W~400W
Min. operating voltage
6V at -30A
CC
Range
-30A~30A
Setup Resolution
10mA
Accuracy
≤0.1%+0.1%FS
CV
Range
0-60V
Setup Resolution
1mV
Accuracy
<0.1% Umax
Internal Resistance
(CV Priority mode)
Range
0-1000mΩ
Setup Resolution
0.1mΩ
Accuracy
2%*Rmax
CP
Range
-400W~400W
Setup Resolution
0.1W
Accuracy
<1.0% Pmax
CR mode(CC Priority
mode)
Range
0.6-1000Ω
Resolution Min.0.1Ω
Accuracy
Rmin(Vreal-Vmax*0.1%)/Rset -Imax*0.2%
Rmax(Vreal+Vmax*0.1%)/Rset +Imax*0.2%
Output Read-back
Read-back current
Range
-30A~30A
Resolution 1mA
Accuracy
≤0.1%+0.1%FS
Read-back Voltage
Range
0-60V
Resolution 1mV
Accuracy
<0.1% Umax
Read-back Power
Range
-400W~400W
Resolution 0.1W
Accuracy
<1% Pmax
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature
Coefficient
100ppm/℃
Copyright © Itech Electronic Co., Ltd.