Do you have a question about the ITech IT-M3140 Series and is the answer not in the manual?
Category | Power Supply |
---|---|
Output Power | 300 W |
Output Current | 0-10 A |
Voltage Resolution | 1 mV |
Current Resolution | 0.1 mA |
Load Regulation (CV) | ≤ 0.01% + 2 mV |
Line Regulation (CV) | ≤ 0.01% + 2 mV |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -20°C to 70°C |
Voltage Accuracy | ≤0.05% + 10 mV |
Current Accuracy | ±0.1% + 10mA |
Display | 4.3-inch LCD |
Interface | RS232 / USB |
Relative Humidity | < 80% |
Model | IT-M3140 |
Details the warranty terms and conditions for the product.
Explains the meaning of safety symbols like CAUTION, WARNING, and NOTE.
Specifies conditions under which the product warranty becomes invalid.
Introduces the IT-M3140 series DC power supply and its key features.
Details the components and functions of the instrument's front panel.
Explains the function of each key on the instrument's keyboard.
Describes the default screen displayed after the instrument's self-test.
Lists and explains various prompt information messages displayed by the instrument.
Details the connectors and interfaces located on the rear panel of the instrument.
Details the settings available within the instrument's configuration menu.
Describes the options and parameters available in the instrument's system menu.
Explains how to configure various protection functions like OVP, OCP, and OPP.
Details advanced functions such as foldback protection and list programming.
Instructions for checking the package contents and condition upon delivery.
Provides dimensional information for instrument installation and rack mounting.
Details how to install the instrument using standard 19-inch rack brackets.
Explains the procedures and precautions for connecting the instrument to AC power.
Describes how to connect the instrument to the device under test using local or remote sensing.
Steps to connect the instrument to a PC using the USB interface.
Instructions for connecting and configuring the instrument's LAN interface.
Information on using socket connections for instrument communication.
Procedures for connecting and setting up the GPIB interface.
Guide to connecting and configuring the instrument using the RS232 interface.
Details the procedure for turning the instrument on and initial self-test.
Instructions on how to set the desired output voltage value for the power supply.
Instructions on how to set the desired output current value for the power supply.
Explains how to navigate and use the instrument's front panel menu system.
Describes how to turn the instrument's output on and off using the front panel.
Covers functions related to output control, including priority modes and delay settings.
Covers general system settings and operations like beep, power-on state, and communication.
Covers the instrument's protection features to safeguard the DUT and the supply.
Enables creation and execution of multi-step test programs using list mode.
Details the optional analog function for remote control and monitoring via interface card.
Lists the primary electrical and performance specifications for each IT-M314x model.
Covers additional characteristics like state storage and calibration frequency.
Explains how to perform an internal self-test to verify system functionality.
Provides guidelines for safely cleaning and maintaining the instrument's exterior and fans.
Provides steps for preparing and contacting technical support in case of instrument failure.
Details the procedures for returning the instrument for warranty or out-of-warranty repair.
Instructions on how to properly repackage the instrument for shipping.
Lists the models, specifications, lengths, and descriptions of optional test cables.