Protect Function
6 Protect Function
Set Over-Voltage Protection
Set Over-Current Protection
Set Over-Power Protection
Set Under-Current Protection
Set Under-Voltage Protection
UUT Over-Temperature Protection
Sense abnormal protection function
Over-Temperature Protection
Set foldback protection
this series power supplies provide the following protection functions. You can
set these functions in the Protect menu. Press [Shift]+[R-set] (Protect) key to
enter into Protect menu. The descriptions of protect menu are listed in the table
below.
Protect Protection function menu
OVP
Over-voltage protection.
Off Turn the OVP function off.
On Level
Over-voltage protection point.
Delay Delay time.
OCP
Over-current protection.
Off Turn the OCP function off.
On Level
Over-current protection point.
Delay Delay time.
OPP
Over-power protection.
Off Turn the OPP function off.
On Level
Over-power protection point.
Delay Delay time.
UUT OTP
UUT Over-temperature protection.
Off Turn the UUT OTP function off.
On Level
UUT OTP point
UCP
Under-current protection.
Off Turn the UCP function off.
On
Warm-up Warm-up time.
Level
Under-current protection point.
Delay Delay time.
Copyright © Itech Electronic Co., Ltd.
63