Technical Specification
Current Temperature
Coefficient
50ppm/℃
Battery Test
AH Measurement
AH Range
0AH-300AH
Accuracy
0.20%
Resolution 0.001AH
Regulation
Load Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Line Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Ripple
Ripple
Voltage ≤100mVp-p
Current ≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
5ms
Rise time
Voltage(Full load)
10ms
Fall time
Voltage(No load)
5ms
Fall time
Voltage(Full load)
5ms
Transient Response
Time
Voltage
≤2mS
Output Protection range
OCP -31A or 31A
OVP 61V
OPP -410W or 410W
External analog (optional)
Voltage programming
External 0V~10V is 0~60V
Voltage monitoring
External 0V~10V is 0~60V
Current programming
External -10V~10V is -30A~30A
Current monitoring
External -10V~10V is -30A~30A
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 2Aac (AC220V)