Technical Specification
Fall time
Voltage(No load)
5ms
Fall time
Voltage(Full load)
5ms
Transient Response
Time
Voltage
≤2mS
Output Protection range
OCP -31A or 31A
OVP 61V
OPP -810W or 810W
External analog (optional)
Voltage programming
External 0V~10V is 0~60V
Voltage monitoring
External 0V~10V is 0~60V
Current programming
External -10V~10V is -30A~30A
Current monitoring
External -10V~10V is -30A~30A
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 4Aac (AC220V)
Power factor PF
>0.98(Lead or Lag)
DC Offset -0.1A~+0.1A
Harmonic THDI <5%
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Noise 60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution 0.1℃
Efficiency
Max. efficiency (Full-load)
86%
Communication(Optional)
Communication interfaces
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters