EasyManuals Logo

ITech IT6513C Manual

ITech IT6513C
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Output Commands
Copyright© Itech Electronics Co., Ltd. 40
[SOURce:]POWer:PROTection:STATe
This command is used to set over power protection state.
Command syntax
[SOURce:]POWer:PROTection:STATe<bool>
Arguments
ON|OFF|1|0
Reset Value
1
Example
POW:PROT:STAT 1
Query syntax
[SOURce:]POWer:PROTection:STATe?
Returns
0|1
[SOURce:]POWer:PROTection[:LEVel]
This command is used to set power value for over power protection.
Command syntax
[SOURce:]POWer:PROTection[:LEVel] <MINimum|MAXimum|DEFault|NRf>
Arguments
MINimum|MAXimum|DEFault|NRf
Unit
w
Query syntax
[SOURce:]POWer:PROTection[:LEVel]? [MINimum|MAXimum|DEFault]
Returns
NRf
[SOURce:]POWer:PROTection:DELay
This command is used to set delay time for over power protection.
Command syntax
[SOURce:]POWer:PROTection:DELay <MINimum|MAXimum|NRf>

Table of Contents

Other manuals for ITech IT6513C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6513C and is the answer not in the manual?

ITech IT6513C Specifications

General IconGeneral
BrandITech
ModelIT6513C
CategoryPower Supply
LanguageEnglish

Related product manuals