Output Commands
Copyright© Itech Electronics Co., Ltd. 41
Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.02
Example
POW: PROT: DEL 2.0
Query syntax
[SOURce:]POWer:PROTection:DELay? [MINimum|MAXimum]
Returns
NRf
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude
]
This command is used to set internal resistance.
Command syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]
<MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
Ohms
Reset Value
MINimum
Example
RES 3.0
Query syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
[MINimum|MAXimum]
Returns
NRf