Load Related CommandIT6500C
Copyright© Itech Electronics Co., Ltd. 55
Unit
A
Reset Value
MAXimum
Example
LOAD:CURR:PROT 24.0
Query syntax
LOAD:CURRent:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
NRf
LOAD:CURRent:PROTection:DELay
This command is used to set delay time for load OCP.
Command syntax
LOAD:CURRent:PROTection:DELay <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
s
Reset Value
0.2
Example
LOAD:CURR:PROT:DEL 0.02
Query syntax
LOAD:CURRent:PROTection:DELay? [MINimum|MAXimum]
Returns
NRf
LOAD:POWer[:LEVel][:IMMediate][:AMPLitude]
This command is used to set the load power.
Command syntax
LOAD:POWer[:LEVel][:IMMediate][:AMPLitude] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf